SP60-1A Industrial Syringe Pump

SP60-1A Industrial Syringe Pump

Speed range:60mm

Flow range:-

Channels:1

Display:-

Control:RS485, RS232,external control input and output

Motor:Stepper motor

Speed range:60mm
Flow range:-
Channels:1
Display:-
Control:RS485, RS232,external control input and output
Motor:Stepper motor

  • Main Functions and Features
  • Selection Guide
  • Service Guarantee
  • Related Products
  • Main SpecUlORongbai Pump
     UlORongbai Pump

    Accuracy:≤1.0 % (syringe ≥1 mL)UlORongbai Pump

    Precision:CV≤0.05% at full stroke (with syringe ≥ 500uL)UlORongbai Pump

    Wetted material:Borosilicate glass,PTFE,PFA,CTFE,ETFE,UHMW-PEUlORongbai Pump

    Dimension (L x W x H):114mm x 65mm x 254mmUlORongbai Pump

    Weight:2.15 kgUlORongbai Pump

    Power supply:DC 24V,1.5A (peak)UlORongbai Pump
     UlORongbai Pump

    Syringe and DriveUlORongbai Pump
     UlORongbai Pump

    Syringe fitting:1/4″-28 threadUlORongbai Pump

    Syringe:50uL, 100uL, 250uL, 500uL, 1mL, 2.5mL, 5mL, 10mL, 25mLUlORongbai Pump

    Syringe material:Borosilicate glass,stainless steel plunger with PTFE coating, PTFE or UHMW-PE plunger tipUlORongbai Pump

    Resolution (standard mode):6000 steps with 0.01mm in 1 stepUlORongbai Pump

    Resolution (microstep mode):48000 microsteps with 1.25um in 1 microstepUlORongbai Pump

    Travel:60mmUlORongbai Pump

    Time for full stroke:1.26s-1200sUlORongbai Pump

    Drive system:Ball screw driveUlORongbai Pump
     UlORongbai Pump

    Valve & Valve DriveUlORongbai Pump
     UlORongbai Pump

    Turn Time:≤250ms between adjacent portsUlORongbai Pump

    Valve options:Standard: 3-port valve, optional: 3-port distribution valve, 4-port valve, T-valveUlORongbai Pump

    Max pressure:0.68MPAUlORongbai Pump

    Fitting:1/4″-28 threadUlORongbai Pump
     UlORongbai Pump

    CommunicationUlORongbai Pump
     UlORongbai Pump

    Interface:RS485, RS232,external control input and outputUlORongbai Pump

    Protocol:Data terminal,OEM protocol (serial) or CANUlORongbai Pump

    Baud rate:"RS485 or RS232: 9600bps or 38400bpsUlORongbai Pump
     UlORongbai Pump

    FirmwareUlORongbai Pump
     UlORongbai Pump

    Topology group:Up to 15 pumps in one group, support group control and individually addressedUlORongbai Pump

    Homing Algorithm:Plunger home position is identified by motor stall, which will reduce the dead volume of the systemUlORongbai Pump

    Halt function:For better interactive control, "h " command is used to halt execution of the command string during plunger movement. To resume execution with "R" or "r" commandUlORongbai Pump
    Microstep modeUlORongbai Pump

    Programmable parameter:Programmable ramps, cut-off velocity, plunger speeds, backlash compensation, programmable work-flow command set , delays and loops, terminate moves, diagnostics, absolute and relative positionsUlORongbai Pump

    UlORongbai Pump
    EnvironmentalUlORongbai Pump
     UlORongbai Pump

    Operating temperature:Recommended: 15℃-40℃ ,use low temperature syringe for low temperature applicationUlORongbai Pump

    Operating Humidity:<80% RH, no condensationUlORongbai Pump

    Storage temperature: -20℃-65℃UlORongbai Pump

    Storage Humidity:<80% RH, no condensationUlORongbai Pump

  • Selection ideas

    1. Confirm the demand flow (mL/min) and the number of pipelines to be transported

    2. Confirm the usage scenario, which can be used directly, or it can be used with the device, controlled by RS485 or external signals

    3. Parameter display, digital tube only shows the speed; LCD screen display flow, speed and other calibration parameters; The touchscreen displays flow, rotational speed, and other programming or configuration parameters

    4. Liquid composition, affect the choice of hose, platinum vulcanized silicone tube recommended for conventional fluids, and imported hoses for corrosive fluids
     

    Choosing a drive to consider

    Flow - The higher the drive speed, the greater the flow rate, select the appropriate drive according to the reference flow

    Control mode - fixed speed; Adjustable speed; Adjustable speed, support flow correction (to achieve precise control of flow); Adjustable speed, support flow distribution (quantitative distribution); Various forms such as external signal control are available

    Parameter display - digital tube, LCD, touch screen

    Protection - Depending on the environment in which it is used, the requirements for sealing, dustproof, and waterproof of the drive should be considered
     

    Choosing a pump head should be considered

    Flow - Select the appropriate pumphead by reference flow

    Hose Change Frequency - With the exception of the OEM series, most pump heads are capable of quick hose changes

    Number of channels suitable - When multi-channel requirements are required, multi-channel pumpheads can be selected or pumpheads can be connected in series

    Chemical Resistance - Considers the effect on the pumphead material when fluid spills
     

    Choosing a hose to consider

    Flow - See the reference flow curve for the hose

    Chemical resistance - choose the material of the hose

    Fluid Temperature - Different materials have different temperature behaviors

    Where a suction lift is required - a high-performance hose should be selected

    Hose life - For different use conditions, hose life performance is different, such as BPT material hose is nearly 30 times more durable than domestic silicone tube

  • About the delivery date

    Peristaltic pumps, syringe pumps, micro plunger pumps, silicone tubes and other products, most of which are in stock, can be delivered within 48 hours;

    Filling machines, filling systems and other products are usually made to order, the inventory is relatively small, the delivery time is about 1 week, and a small part is in stock;

    Common models of imported hose series products are in stock; Because the imported hose is affected by international logistics, under special circumstances, the delivery time is about 1~4 weeks;

    Remarks: All peristaltic pump series products need 3 days of non-stop operation and aging before leaving the factory, so as to ensure a lower failure rate and let customers use it with confidence
     

    About after-sales

    One year warranty (except for consumables, improper use or man-made damage is not covered by the warranty)

    Due to special circumstances such as traffic differences, use environment, personal reasons and other special circumstances due to selection or actual application, you can directly contact customer service for exchange without affecting secondary sales
     

    About logistics (applicable in China)

    Default Debang/SF delivery, please communicate with customer service and confirm special needs