BS100-1AQ Peristaltic Pump
Speed range:0.1~100 rpm
Flow range:≤164mL/min
Channels:1
Display:3-digit LED displays current rpm
Control:Control panel / External control signal
Motor:Stepper motor
- Main Functions and Features
- Selection Guide
- Service Guarantee
- Related Products
-
Speed: 0.1 to 100 rpm, reversible
Speed precision: 0.1 rpm
Speed control: Membrane keypad
Display: 3-digit LED displays current rpm
Communication interface: RS485
External control: Start/stop, cw/ccw control and speed control 0-5 V, 0-10 V, 4-20 mA and 0-10KHz
Power supply: AC 90V-260 V 50/60 Hz
Power consumption: ≤30 W
Operating condition: Temperature 0 to 40 ℃ ; Relative humidity < 80%
Dimensions: 186×110×143 (mm)
Drive weight: 1.3 kg
IP rating: IP 31
Pump head and Flow rate
Pump Head:JY15
Tube code:16# 25#
Flow Range(ml/min):≤164
Channel Number:1
Pump Head:WX10
Tube code:Wall Thickness: 0.8 - 1 mm;Inner Diameter ≤3.17 mm
Flow Range(ml/min):0.0025 - 41
Channel Number:1
The main factors affecting the flow of peristaltic pumps are:
1. The speed of the drive;
2. The selection of pump head;
3. The diameter of the hose;
The higher the speed of the drive, the greater the flow rate;
At the same speed, the larger the diameter of the hose, the greater the flow rate;
Different types of pump heads are suitable for different hoses.
-
Selection ideas
1. Confirm the demand flow (mL/min) and the number of pipelines to be transported
2. Confirm the usage scenario, which can be used directly, or it can be used with the device, controlled by RS485 or external signals
3. Parameter display, digital tube only shows the speed; LCD screen display flow, speed and other calibration parameters; The touchscreen displays flow, rotational speed, and other programming or configuration parameters
4. Liquid composition, affect the choice of hose, platinum vulcanized silicone tube recommended for conventional fluids, and imported hoses for corrosive fluids
Choosing a drive to consider
Flow - The higher the drive speed, the greater the flow rate, select the appropriate drive according to the reference flow
Control mode - fixed speed; Adjustable speed; Adjustable speed, support flow correction (to achieve precise control of flow); Adjustable speed, support flow distribution (quantitative distribution); Various forms such as external signal control are available
Parameter display - digital tube, LCD, touch screen
Protection - Depending on the environment in which it is used, the requirements for sealing, dustproof, and waterproof of the drive should be considered
Choosing a pump head should be considered
Flow - Select the appropriate pumphead by reference flow
Hose Change Frequency - With the exception of the OEM series, most pump heads are capable of quick hose changes
Number of channels suitable - When multi-channel requirements are required, multi-channel pumpheads can be selected or pumpheads can be connected in series
Chemical Resistance - Considers the effect on the pumphead material when fluid spills
Choosing a hose to consider
Flow - See the reference flow curve for the hose
Chemical resistance - choose the material of the hose
Fluid Temperature - Different materials have different temperature behaviors
Where a suction lift is required - a high-performance hose should be selected
Hose life - For different use conditions, hose life performance is different, such as BPT material hose is nearly 30 times more durable than domestic silicone tube
-
About the delivery date
Peristaltic pumps, syringe pumps, micro plunger pumps, silicone tubes and other products, most of which are in stock, can be delivered within 48 hours;
Filling machines, filling systems and other products are usually made to order, the inventory is relatively small, the delivery time is about 1 week, and a small part is in stock;
Common models of imported hose series products are in stock; Because the imported hose is affected by international logistics, under special circumstances, the delivery time is about 1~4 weeks;
Remarks: All peristaltic pump series products need 3 days of non-stop operation and aging before leaving the factory, so as to ensure a lower failure rate and let customers use it with confidence
About after-sales
One year warranty (except for consumables, improper use or man-made damage is not covered by the warranty)
Due to special circumstances such as traffic differences, use environment, personal reasons and other special circumstances due to selection or actual application, you can directly contact customer service for exchange without affecting secondary sales
About logistics (applicable in China)
Default Debang/SF delivery, please communicate with customer service and confirm special needs
-
BT100 peristaltic pump
Speed: 0.1 to 150 rpm, reversibleSpeed precision: 0.1 rpmSpeed control: Membrane keypadD
BT100K peristaltic pump
Speed: 0.1 to 150 rpm, reversibleSpeed precision: 0.1 rpmSpeed control: Membrane keypadD
BT50S peristaltic pump
Speed: 0.1 to 50 rpm, reversibleSpeed precision: 0.1 rpmSpeed control: Membrane keypadDi
BT100-2J Laboratory peristaltic pump
Speed: 0.1 to 100 rpm, reversibleSpeed precision: 0.1 rpmSpeed control: Membrane keypadD
ST600S Peristaltic Pump
Speed: 1 to 600 rpm, reversibleSpeed precision: 1 rpmSpeed control: Membrane keypadDispl
ST300S Peristaltic Pump
Speed: 1 to 350 rpm, reversibleSpeed precision: 1 rpmSpeed control: Membrane keypadDispl
BT100SG peristaltic pump IP65
Speed: 0.1 to 100 rpm, reversibleSpeed precision: 0.1 rpmSpeed control: Membrane keypadD
BT600K peristaltic pump
Speed: 0.1 to 600 rpm, reversibleSpeed precision: 0.1 rpm(<100rpm);1 rpm(≥100rpm)Speed