Variable Speed OEM peristaltic pump T600-B

Variable Speed OEM peristaltic pump T600-B

Speed range:≤600rpm

Flow range:≤2280mL/min

Channels:1/2

Display:-

Control:BCD / External control signal

Motor:Stepper motor

Speed range:≤600rpm
Flow range:≤2280mL/min
Channels:1/2
Display:-
Control:BCD / External control signal
Motor:Stepper motor

  • Main Functions and Features
  • Selection Guide
  • Service Guarantee
  • Related Products
  • Speed:≤600rpmueORongbai Pump

    Speed resolution:0.1rpmueORongbai Pump

    Direction control:Direction is controlled by external switch signal. CW when switch is open,CCW when switch is closed.ueORongbai Pump

    Start/stop control:Start/stop is controlled by external switch signal. Pump runs when switch is open,stops when switch is closed. ueORongbai Pump

    Operating condition: Temperature 0 to 40 ℃ ; Relative humidity < 80%ueORongbai Pump

    Power supply:DC24 VueORongbai Pump

    Communication interface: RS485ueORongbai Pump

    Power consumption: ≤50 WueORongbai Pump

    Dimensions: 163×102×136 (mm)ueORongbai Pump

    Drive weight: 1 kgueORongbai Pump
     ueORongbai Pump

    BCD dial switch speedueORongbai Pump
     ueORongbai Pump

    control:The speed is divided into 15 grades. BCD position 1-F corresponding to (rpm)40,80,120,160,200,240,280,320,360,400,440,480,520,560,600 (rpm)ueORongbai Pump
     ueORongbai Pump

    External speed controlueORongbai Pump
     ueORongbai Pump

    (optional):4-20mA corresponding to 0.1-600rpm, 0-5V corresponding to 0-600rpm、0-10V corresponding to 0-600rpm, 0-10kHz corresponding to 0-500rpmueORongbai Pump
     ueORongbai Pump

    Pump head and Flow rateueORongbai Pump
     ueORongbai Pump

    Pump Head:YZ1515ueORongbai Pump

    Tube code:13# 14# 19# 16# 25# 17# 18#ueORongbai Pump

    Flow Range(ml/min):≤2280/ single passageueORongbai Pump

    Channel Number:1/2ueORongbai Pump

     ueORongbai Pump

    Pump Head:YZ2515ueORongbai Pump

    Tube code:15# 24#ueORongbai Pump

    Flow Range(ml/min):≤1600/ single passageueORongbai Pump

    Channel Number:1/2ueORongbai Pump

    ueORongbai Pump
     ueORongbai Pump

    The main factors affecting the flow of peristaltic pumps are:ueORongbai Pump

    1. The speed of the drive;ueORongbai Pump

    2. The selection of pump head;ueORongbai Pump

    3. The diameter of the hose;ueORongbai Pump

    The higher the speed of the drive, the greater the flow rate;ueORongbai Pump

    At the same speed, the larger the diameter of the hose, the greater the flow rate;ueORongbai Pump

    Different types of pump heads are suitable for different hoses.ueORongbai Pump

  • Selection ideas

    1. Confirm the demand flow (mL/min) and the number of pipelines to be transported

    2. Confirm the usage scenario, which can be used directly, or it can be used with the device, controlled by RS485 or external signals

    3. Parameter display, digital tube only shows the speed; LCD screen display flow, speed and other calibration parameters; The touchscreen displays flow, rotational speed, and other programming or configuration parameters

    4. Liquid composition, affect the choice of hose, platinum vulcanized silicone tube recommended for conventional fluids, and imported hoses for corrosive fluids
     

    Choosing a drive to consider

    Flow - The higher the drive speed, the greater the flow rate, select the appropriate drive according to the reference flow

    Control mode - fixed speed; Adjustable speed; Adjustable speed, support flow correction (to achieve precise control of flow); Adjustable speed, support flow distribution (quantitative distribution); Various forms such as external signal control are available

    Parameter display - digital tube, LCD, touch screen

    Protection - Depending on the environment in which it is used, the requirements for sealing, dustproof, and waterproof of the drive should be considered
     

    Choosing a pump head should be considered

    Flow - Select the appropriate pumphead by reference flow

    Hose Change Frequency - With the exception of the OEM series, most pump heads are capable of quick hose changes

    Number of channels suitable - When multi-channel requirements are required, multi-channel pumpheads can be selected or pumpheads can be connected in series

    Chemical Resistance - Considers the effect on the pumphead material when fluid spills
     

    Choosing a hose to consider

    Flow - See the reference flow curve for the hose

    Chemical resistance - choose the material of the hose

    Fluid Temperature - Different materials have different temperature behaviors

    Where a suction lift is required - a high-performance hose should be selected

    Hose life - For different use conditions, hose life performance is different, such as BPT material hose is nearly 30 times more durable than domestic silicone tube

  • About the delivery date

    Peristaltic pumps, syringe pumps, micro plunger pumps, silicone tubes and other products, most of which are in stock, can be delivered within 48 hours;

    Filling machines, filling systems and other products are usually made to order, the inventory is relatively small, the delivery time is about 1 week, and a small part is in stock;

    Common models of imported hose series products are in stock; Because the imported hose is affected by international logistics, under special circumstances, the delivery time is about 1~4 weeks;

    Remarks: All peristaltic pump series products need 3 days of non-stop operation and aging before leaving the factory, so as to ensure a lower failure rate and let customers use it with confidence
     

    About after-sales

    One year warranty (except for consumables, improper use or man-made damage is not covered by the warranty)

    Due to special circumstances such as traffic differences, use environment, personal reasons and other special circumstances due to selection or actual application, you can directly contact customer service for exchange without affecting secondary sales
     

    About logistics (applicable in China)

    Default Debang/SF delivery, please communicate with customer service and confirm special needs