TSP01-08 Syringe Pump System

TSP01-08 Syringe Pump System

Stroke of the drive unit:-

Flow range:-

No. of Syringes:1/2/3/4/5/6/7/8

Display:7 inch LCD touchscreen

Control:Touch Panel / External control signal

Motor:Stepper motor

Stroke of the drive unit:-
Flow range:-
No. of Syringes:1/2/3/4/5/6/7/8
Display:7 inch LCD touchscreen
Control:Touch Panel / External control signal
Motor:Stepper motor

  • Main Functions and Features
  • Selection Guide
  • Service Guarantee
  • Related Products
  • TSP01-08/W0109 syringe pump system is four-channel micro syringe pump. The pump could hold glass or plastic syringes from 10ul to 60ml. The features of accurate distance control and broad linear speed range (3um/min-130mm/min) can meet versatile requirement. The eight drive units could operate independently, which are easily installed and combined and could meet different operation requirements.yO2Rongbai Pump
     yO2Rongbai Pump

    Main Functions and FeaturesyO2Rongbai Pump
     yO2Rongbai Pump

    User-defined Syringe: Storing 8 inner diameters of user-defined syringeyO2Rongbai Pump

    Linear Force Output: > 90 NyO2Rongbai Pump

    Adopt 7 inch LCD touchscreen, easy to operateyO2Rongbai Pump

    Memory Function: Storing the running parameters automaticallyyO2Rongbai Pump

    Calibration: Acquire accurate volume through calibrationyO2Rongbai Pump

    Fast forward & fast reverse: Infusion or withdrawal at the max. SpeedyO2Rongbai Pump
     yO2Rongbai Pump

    Technical SpecificationsyO2Rongbai Pump
     yO2Rongbai Pump

    Max. Infusion Distance: 90 mmyO2Rongbai Pump

    Acceptable Sample Syringe: 10µl – 60mlyO2Rongbai Pump

    Linear Force: > 90 NyO2Rongbai Pump

    Setting Mode: 7 inch LCD touchscreenyO2Rongbai Pump

    Display: 7 inch LCD touchscreenyO2Rongbai Pump

    Communication Interface: RS485yO2Rongbai Pump

    Operating Condition: Temperature 5℃ to 40°C,yO2Rongbai Pump

    relative humidity: 20% - 80% RHyO2Rongbai Pump

    Controller Dimensions: 245 x 190 x 95 (mm)yO2Rongbai Pump

    Drive unit Dimensions: 250 x 100 x 101 (mm)yO2Rongbai Pump

  • Selection ideas

    1. Confirm the demand flow (mL/min) and the number of pipelines to be transported

    2. Confirm the usage scenario, which can be used directly, or it can be used with the device, controlled by RS485 or external signals

    3. Parameter display, digital tube only shows the speed; LCD screen display flow, speed and other calibration parameters; The touchscreen displays flow, rotational speed, and other programming or configuration parameters

    4. Liquid composition, affect the choice of hose, platinum vulcanized silicone tube recommended for conventional fluids, and imported hoses for corrosive fluids
     

    Choosing a drive to consider

    Flow - The higher the drive speed, the greater the flow rate, select the appropriate drive according to the reference flow

    Control mode - fixed speed; Adjustable speed; Adjustable speed, support flow correction (to achieve precise control of flow); Adjustable speed, support flow distribution (quantitative distribution); Various forms such as external signal control are available

    Parameter display - digital tube, LCD, touch screen

    Protection - Depending on the environment in which it is used, the requirements for sealing, dustproof, and waterproof of the drive should be considered
     

    Choosing a pump head should be considered

    Flow - Select the appropriate pumphead by reference flow

    Hose Change Frequency - With the exception of the OEM series, most pump heads are capable of quick hose changes

    Number of channels suitable - When multi-channel requirements are required, multi-channel pumpheads can be selected or pumpheads can be connected in series

    Chemical Resistance - Considers the effect on the pumphead material when fluid spills
     

    Choosing a hose to consider

    Flow - See the reference flow curve for the hose

    Chemical resistance - choose the material of the hose

    Fluid Temperature - Different materials have different temperature behaviors

    Where a suction lift is required - a high-performance hose should be selected

    Hose life - For different use conditions, hose life performance is different, such as BPT material hose is nearly 30 times more durable than domestic silicone tube

  • About the delivery date

    Peristaltic pumps, syringe pumps, micro plunger pumps, silicone tubes and other products, most of which are in stock, can be delivered within 48 hours;

    Filling machines, filling systems and other products are usually made to order, the inventory is relatively small, the delivery time is about 1 week, and a small part is in stock;

    Common models of imported hose series products are in stock; Because the imported hose is affected by international logistics, under special circumstances, the delivery time is about 1~4 weeks;

    Remarks: All peristaltic pump series products need 3 days of non-stop operation and aging before leaving the factory, so as to ensure a lower failure rate and let customers use it with confidence
     

    About after-sales

    One year warranty (except for consumables, improper use or man-made damage is not covered by the warranty)

    Due to special circumstances such as traffic differences, use environment, personal reasons and other special circumstances due to selection or actual application, you can directly contact customer service for exchange without affecting secondary sales
     

    About logistics (applicable in China)

    Default Debang/SF delivery, please communicate with customer service and confirm special needs